ARCUS — Bridge Failure Research

ARCUS Atlas record

Ponte di Calciano

This record concerns Ponte di Calciano in Calciano. Recorded date: 1 March 2011. ARCUS outcome classification: PC. Recorded cause category: Hydraulic. Reported trigger: Flood. Reported process: Scour. Reported component: Multiple components. Recorded fatalities: 0; injuries: 0. Cause evidence: Documented.

Documentary notes and limitations

The classification in supplementary dataset S3 by D’Angelo, Ballio and Ravazzani (2025), record P146, is attributed to its authors and is not a new ARCUS measurement.

ARCUS ID
IT11.03.01
Date
2011-03-01
Municipality
Calciano
Province
Matera
Region
Basilicata
Coordinates
40.5977, 16.1845 · exact location
Crossing
Basento river
Use
National
Severity
PC
Structural type
Beam bridge
Material
Reinforced concrete
Cause category
Natural
Specific cause
Hydraulic
Failure trigger
Flood
Failure process
Scour
Component involved
Multiple components
Cause evidence
Documented
Source confidence
Medium
Victims
0
Injuries
0

Sources and scientific context (4)

  1. Event documentation: Ponte di Calciano (Official/Technical · senato.it)
  2. Il ponte di Calciano: un problema non risolto (News · Il Resto · 2011-05-07)
  3. Basentana, demolito il pilone ferito (News · La Gazzetta del Mezzogiorno · 2011-04-07)
  4. Geomorphologic risk factors for river bridges (2025), supplementary dataset S3 P146 (Scientific · D'Angelo, Ballio & Ravazzani)

Return to the Atlas · Propose a correction or new evidence